WFCCD GUI Documentation - Release Notes
Location of this document:
http://instrumentation.obs.carnegiescience.edu/Software/WFCCD/notes.html
Version History
v2.1,
v2.0
v1.5 and older
v2.1 (2018-05-10)
- Modified the "subraster" record of the FITS header to indicate
the actual subraster geometry even if the full ('0' padded)
frame is saved.
- SUBRASTR='[x1:x2,y1:y2]'
- "Trim bias section from loaded FITS files" option on the
Preferences/QuickLook pane.
- This allows to display the bias sections (overscan and biaslines)
in the QuickLookTool for FITS files loaded from disk
(not for data directly read from the array).
v2.0.3 (2017-05-19)
- Enforce unique filter/aperture names.
v2.0.2 (2017-03-21)
- Changed the permissions of the logfile to read/write all.
- This allows different observer accounts to append to a pre-existing logfile.
- Fixed a bug in the routine that requests the password for enabling
- the engineering mode (required to change the CCD voltages).
v2.0.1 (2017-03-03)
- Changed the file permissions of saved subrasters to read/write all.
- This allows different observer accounts to overwrite pre-existing
subraster definition files.
- All accounts write to the same 'Subrasters' directory in
/Users/Shared/Library/Applictaion Support/WFCCD/
v2.0 (2017-02-28)
- Installed the official release version of the new WFCCD GUI.
v2-beta-0019 (2017-02-24)
- Successfuly tested by Patrcio Pinto (Feb/27) -- Thanks!
v2-beta-0016 (2017-01-31)
- Moves the wheels sequentially (internal interlock).
- Changed the communication with the wheel controller.
v2-beta-0013 (2017-01-25)
- Allow to change the wheels during exposure/readout.
- Changed the communication with the wheel controller.
v2-beta-0012 (2017-01-24)
- Ported the WFCCD (ccdgui, X11) to macOS/Cocoa.
- Added FITS records:
- FFLAMPS : flat field lamps from the M2-GUI.
- M2FOCUS : M2 focus from the M2-GUI.
- DATASEC, TRIMSEC : standard NOAO keywords.
- Changed FITS records: --- please let me know if this creates a problem ---
- SITELONG = -70.70384 (was -70.70387)
- Removed FITS records: --- please let me know if this creates a problem ---
- ASECS, DSECS, VGAUGE, IGAUGE
- These keywords do not have any meaning in the context of the WFCCD instrument
and were only in the FITS header because the ccdgui is shared between
multiple instruments.
- Default data path is
/Volumes/DATA_DUPONT/WFCCD/utYYMMD1_D2.
- Open the data path(s) in a Finder window via the
File--Show DataFolder menu.
- Interaction with the
M2-GUI:
- Read the FF-Lamp status and M2-Focus from the
M2-GUI running on vinchuca (iMac on TO console).
These are written to the FITS header (keywords: FFLAMPS, M2FOCUS).
- Interaction with the
TeleGUI:
- Please offset the M2-focus via the TeleGUI:
- The Object and Comment edit fields on the GUI are
automatically filled with the values in the ObjectList of the
TeleGUI when the SendToTCS button is pressed.
- The SkyMap displays the position of each exposure onto the SkyMap
as a green rectangle the size of the CCD array.
v1.5 and older
Christoph C. Birk, Carnegie Observatories